What Does Bx Cable Mean?

December 5, 2021

bx cable definition

NM and NMC conductors are composed of two or more insulated conductors contained in a non-metallic sheath. The coating on NMC cable is non-conducting, flame-resistant and moisture-resistant. Unlike other cables commonly found in homes, they are permitted in damp environments, contra asset account such as basements. There were originally two initial versions of armored cable. One was called “AX” and the other “BX,” with the “X” standing for “experimental.” The “BX” version became the one that eventually was produced, and hence the name “BX” became the common name.

In some types of fixtures, both wires will be the same color. Romex is used for most lighting and outlet circuits in your home. EMT is also called "thin-wall" conduit becauseit is thin and lightweight, especially compared to RMC. EMTis rigid but can be bent with a simple tool called a conduitbender. EMT is installed with couplings and fittings thatare secured with setscrew or compression-typefasteners. Traditional Type MC cable is manufactured to ULStandard 1569.

  • The flex stretched into a coil and the internal ground conductor pulled out of the terminal at one end.
  • Armored cable and metal clad cable provide a fast and efficient way of wiring both new construction and remodeling work.
  • Some even go as far to turn off the circuits to their bedrooms when they sleep to reduce their exposure.
  • It is permitted in wet locations and underground where identified for such use.

I was wondering when/if conduit is required instead of BX. For me, its just way faster easier to run BX, but I’ll do conduit if I have to. AC90 is a cost effective alternative to conduit wiring. AC90 eliminates the need for conduit, fittings and the labour associated with pulling in wire, threading, and forming conduit. Multiconductor and special construction AC90 can be manufactured.

Electrical Wires & Cables

Electrical Metallic Conduit is technically a tubing, not a type of conduit, although electricians talk about “putting the wire in conduit” and it is understood that they mean EMT. It is a thin-wall tubing, aluminum, stainless steel, or usually steel with a protective coating. Cable size is the gauge of individual wires within the cable, such What is bookkeeping as 14, 12, 10 etc. – again, the bigger the number, the smaller the size. So, 10/3 would indicate the presence of 3 wires of 10-gauge within the cable. Ground wire, if present, is not indicated by this number, and is represented by the letter ‘G’. An electrical cable also has different types, color and application as its determining factors.

The hospital grade AC cable is the second variety of flexible armored cable developed by AFC called HCF. This HCF cable is designed for use not just in hospitals but also for other patient care areas.

I still strongly suspect that the building being discussed has MC or AC cable, rather than flex. One would have to see the fittings, as well as inside the junction boxes, to tell. It looks neater, is easier to pull wire through, and you can pull any sort of wire you like. Under certain conditions, the conduit can also serve as the ground path. All of the existing wiring in the space goes UP from the box to the ceiling, then over to wherever and down, and all of that is BX wiring.

Type EMT is suitable for branch circuits, feeders and services, and is used in sensitive areas such as elevator shafts and health-care facilities, and in some but not all classified areas. It is very widely used in commercial and industrial wiring, and for residential services. Compared to Rigid Metal Conduit , EMT is far less expensive and much easier to install. Segments can be marked with a fine-point felt-tipped pen and cut with a hacksaw, then reamed to remove sharp edges on the interior that could damage wire insulation. In commercial I usually see EMT in new construction and MC cable for retro work, simply because it is easier to fish. FMC is usually only used for short whips since it is hard to get wire stuffed through if any length is involved.

One really has to stop and be intentionally specific to make sure one is discussing the correct wiring method so as to cite the proper provision of code. Just another of the many reasons why it is so important to consider the precision of code language when describing a condition, method, citation, etc. I ran into an entire system in a high-rise condo today. At first glance into the panel I was perplexed at the lack of ground wires.

They are not permitted inside homes, with the exception of “style R” SE cable that can serve as interior wiring in branch circuits for ovens and clothes dryers. Style R cables should be clearly marked on their jacket surfaces. Commonly known as SWA cable, the steel wire armoured cable is a power and auxiliary control cable, designed for use in mains supply electricity. Used for underground systems, cable networks, power networks, outdoor and indoor applications, and cable ducting. NM cable is permitted to be run exposed on thesurface of the building finish. If subject to physical damage thenit requires supplemental protection.

Outlet was grounded when attached to the box but became ungrounded when not on contact . An MC cutter is needed to cut the sheath with no danger of nicking the conductor insulation. As to normal balance why the engineer specified something, you'd have to ask him. I am not aware of any location where pipe cannot be used as a general wiring method in place of any of the "flexible" methods.

Code Q&a: Listing Requirements For Type Mc Cable

Armored cable was first listed with Underwriters Laboratories Inc. in 1899 for the Sprague Electric Co. of New York. It was originally called “Greenfield Flexible Steel-Armored Conductors,” after one of its inventors, Harry Greenfield. During a Chelan Home Inspection I came across the use of what is often called BX cable. Change the date range, chart type and compare The Blackstone Group L.P. Commo against other companies.

bx cable definition

It is very easy to transition between these two complementary wiring methods. Splices can be made in light fixture enclosures, wall boxes, or junction boxes.

The Differences Between Grounding And Bonding

MC can have a smooth or corrugated metallic sheath or, most commonly, interlocking metal tape armor. The sheath may be steel or aluminum, which is non-magnetic and therefore suitable when used with a single conductor, so as to avoid an induced voltage on the sheath. MC is also availible as HFC cable which has a bonding strip as well as a full sized ground. This cable can be used in a patient care area or for an isloated ground circuit. Individual conductors run inside conduit is used primarily in industrial and commercial applications, and is rarely used in residential wiring.

bx cable definition

However as mentioned previously armored cable first discussed 1903 not 1905. Here is something I stated "my 1905 NEC does reference AC ", you then stated "I don't believe the term type AC showed up until the 30s." Although 1959 is important regarding the bonding wire no distinction btwn MC or AC prior, 1990s changes are more important regarding EGC. The earlier bonding "wire" was a flat ribbon subject to breakage - cannot be relied upon for safety or as EGC. AX like another form of flexible armor-tubes used for other uses, but when used for electric wiring in structures had a problem.

Is Mc Cable Suitable For Damp Locations?

These devices are not designed to remain in place with or without the lock installed. This type of device must be removed in order to close a panel­board cover and in some cases must be removed in order to remove the panelboard deadfront. In the case of a two-pole 30A circuit breaker, an accessory device must be purchased from the circuit breaker manufacturer and installed over the circuit breaker. All manufacturers of circuit breakers have a line of accessory devices that include a means to apply locks. These devices will be placed over the circuit breaker before the deadfront goes on and will remain in place with or without the lock applied.

What Type Wire Is In Mc Cable?

The Rome came from the town in New York and plant name where the wire was manufactured originally. Keep in mind that the AC cable is required to have a anti short bushing also. Member NEC panel decided that the contact of the 2 bolts that attach the receptacle yoke to the box does not create a "robust" ground.

Larger circuit breakers can be custom ordered with a means to apply a lock installed on the circuit breaker itself. If you lay the BX out straight, strip out one end, clamp the wires in a vise, then pull the outer jacket off. This same problem is a real issue where people have attempted to use the armor as a ground because if the insulation fails on the hot wire you may in fact have a potential on the armor.

Older BX cables without an internal bonding strip arenot accepted by NEC. Today, residential construction primarily uses three types of wiring, Non-Metalliccable being the most common; followed by BX , and individual conductors run inside conduit. In Part One I discussed knob and tube wiring and the potential problems and issues that may arise if your home still contains legacy knob and tube. Perhaps your home bx cable definition still contains knob and tube, or you are considering remodeling or planning new construction. In this article, I will explain current options and residential wiring best practices. Type AC cable is approved by the NEC for use only in dry locations. In order to comply with the NEC for use in wet locations, interlocked Type MC Cable must have a corrosion resistant jacket and wet location rated conductors.

If you have to tear out a wall to replace a wire that has been punctured by a nail, supposing you were hanging a picture, this repair could cost well over $1,000. Many of my concerned clients have spent a lot of effort and money to shield against and reduce their exposure to electric fields. Some even go as far to turn off the circuits to their bedrooms when they sleep to reduce their exposure.

The use of removable carpet squares makes access to FCC easy, as one need only pull up one corner of the carpet square. In schools and residential occupancies, this could lead to easy access by children who pull up the carpet.

InterNACHI inspectors should understand the basic distinctions between the different types of cable systems so that they can identify unsafe conditions. BX is as good as NM cable from a Magnetic Field standpoint but has the added benefit of shielding Electric Fields .

It consists of individual, insulated conductors pulled from a spool through a conduit, either metal or PVC. This is a more difficult and time-consuming wiring method but is more efficient in commercial applications where wiring runs must be exposed and thus must be inside some form of conduit. The wire is protected by 2 layers of insulation, with each individual conductor being insulated and the entire bundle also being insulated.

In summary, inspectors should understand the different types of conductors that are commonly found in homes. Disregarding any inherent inadequacies, existing KT cable systems are likely to be unsafe because they are almost guaranteed to be at least 50 years old. Some insurance companies refuse to write fire insurance for houses with this type of wiring, although this may be remedied if an electrician can verify that the system is safe. Knob-and-tube wiring is more vulnerable to damage than modern wiring because it is insulated with fiber materials and varnish, which can become brittle. Support devices that may damage the cables, such as bent nails and overdriven staples, are not permitted. They must be protected, secured and clamped to device boxes, junction boxes and fixtures.

If the architect, owner, or contractor had insisted on BX instead of NM cable, this repair would likely not have been necessary. There is also FMC, called by the slang of "Greenfield" that comes without conductors installed.